Metal Light Switch Earthing: Does Your Plate Need One?

By Kent Traders · Updated 27 October 2026 · 7 min read · UK

A plastic light switch needs no earth connection. A metal one does. Metal light switch earthing catches out people who swap a plastic plate for a Nexus Metal one and expect the same two or three wires to do the job. The plate itself is now a conductor, and it needs somewhere to send a fault.

Quick answer

Yes, a metal light switch needs earthing. BG's Nexus Metal instructions require an earth connection between the front plate and the back box, and a link from the box earth terminal to the accessory earth terminal where one is fitted. No earth at the box means no metal plate.

5Nexus Metal finish codes: NAB, NBN, NBS, NFB and NPC
16mmminimum box depth for one and two gang profiled plates
2earth terminals listed on the BG NBS52 fused spur

Does a metal light switch need earthing?

Yes. The reason is simple. If a live conductor touches a metal plate, the plate becomes live. A connected earth conductor gives that fault current a path back to the consumer unit, so the protective device trips instead of the next person touching the plate.

A plastic plate cannot carry that fault, which is why plastic switches get away without an earth. Swap it for metal and the rule changes. The wiring behind the wall has to supply an earth, and you have to connect it.

What BG's instructions say about metal light switch earthing

BG's instruction sheet for its Nexus plate switches is short, and most of it is about earthing. We read the BG plate switch instructions and summarised the relevant points below.

BG instruction What it means for you
Earth the mounting box to the accessory Link the box earth terminal to the accessory earth terminal where one is fitted
Decorative products need a front plate link Make an earth connection between the front plate and the back box
Sleeve bare earth wires Cover every bare earth wire with green and yellow sleeving
Keep the protective conductors continuous Do not break the earth path between the circuit and the box
Four-lug metal box Remove the top and bottom lugs, or bend them fully back
Isolate at the consumer unit Switch off the circuit before you open the box
Use a competent person Choose one registered with an electrical self-certification scheme
Rule

On a metal Nexus plate, the earth path is not optional. No earth at the back box means a plastic plate until an electrician has fixed the circuit.

Why a metal plate changes the rules

Older houses often have lighting circuits wired in two-core cable, with no earth conductor at the switch. Plastic switches never needed one, so nobody ran it. Later rewires normally use twin and earth, which carries a bare earth conductor to every switch box.

That difference decides whether a metal plate is simple or a job for a professional. Open the box and look. Is there a bare or sleeved earth conductor, and does it reach the box?

What you find Metal plate? Next step
Earth conductor in the box, connected Yes Make the BG earth links and test
Earth conductor present but unconnected Not yet Have it connected and tested first
No earth conductor in the box No Keep plastic and ask a registered electrician
Metal box, no earth terminal No Electrician to check the box and circuit

Our Part P guide says a like-for-like switch replacement is not notifiable in England. In our reading, a plastic-to-metal swap is more than like for like, because it adds an earthing requirement. The work must still meet BS 7671 either way.

Which Nexus Metal switches this covers

BG's Nexus Metal switches come in five finishes. The first letters name the finish, and the digits give the function. The earth rules above apply across the range, so the finish does not change them.

Prefix Finish Example
NAB Antique brass NAB12
NBN Black nickel NBN12
NBS Brushed steel NBS12
NFB Matt black NFB12
NPC Polished chrome NPC12

Box depth matters just as much as the earth link. BG's manual gives 16mm for profiled one and two gang plates and 25mm for three, four and six gang. Its specification sheet lists 16mm against the 43 code, which conflicts with the manual for three gang, so fit 25mm there. Our NBS12 page says it needs a 16mm metal wall box.

Watch out

Some of our own listings contradict themselves on depth. The NBS15 fan isolator page says 16mm in the text and 25mm in the table. Check the instruction sheet in the box before you fix.

Worked example: a three-switch staircase

Take a staircase with a switch at the bottom, one at the top and one on the landing. Assume the existing plates are plastic and the house has twin and earth wiring. That needs two 2-way switches and one intermediate.

Position Switch Price Earth links
Bottom of stairs BG NBS12, 2 way £3.76 Box to plate
Landing BG NBS13, intermediate £5.95 Box to plate
Top of stairs BG NBS12, 2 way £3.76 Box to plate
Total Three plates £13.47 Three links

Parts come to £13.47 at our prices on 27 October 2026. The cost that matters is the earth work. That is three boxes, three links and three sleeved conductors, and every one must be right before the circuit goes back on.

  1. Isolate the lighting circuit at the consumer unit and prove it dead.
  2. Open each box and confirm an earth conductor is present and connected.
  3. Sleeve any bare earth wire with green and yellow sleeving.
  4. Make the earth link from the back box to the front plate, as BG's sheet requires.
  5. Fit the plate, check no earth conductor is trapped, then test continuity before you switch on.
Installer tip

Do the earth link first, before you fold the cables into the box. Shallow 16mm boxes leave little room for a loose sleeved wire afterwards.

Where metal switch jobs go wrong

Metal switch jobs go wrong in a few predictable ways. Almost all of them come from treating the plate like a plastic one.

  • Fitting a metal plate to a box with no earth. This is the big one. Stop and get the circuit checked.
  • Leaving bare earth wire unsleeved. BG requires green and yellow sleeving on every bare earth wire.
  • Skipping the front plate link. BG says decorative products must have it, so the box terminal alone is not enough.
  • Leaving four-lug box lugs standing. Remove the top and bottom lugs or bend them fully back.
  • Using a box that is too shallow. A cramped box squashes the conductors and the sleeving.
  • Assuming the accessory has an earth terminal. Our NBS12 and NBS13 pages label none, so follow BG's instruction sheet.

What to buy: BG Nexus Metal switches

The Nexus Metal brushed steel collection holds 294 products, all in stock on 27 October 2026. For other switch styles, browse light switches or the fused switches. These six cover switches, sockets and a fan isolator.

Code What it is Price
BG NBS12 Brushed steel, 1 gang, 10AX 2 way plate switch £3.76
BG NBS13 Brushed steel, 1 gang, 10AX intermediate plate switch £5.95
BG NBS15 Brushed steel, 1 gang, 10AX 3 pole fan isolator switch £8.58
BG NBS21W Brushed steel, 1 gang, 13A switched socket, white insert £5.67
BG NBS22W Brushed steel, 2 gang, 13A switched socket, white insert £6.56
BG NBS52 Brushed steel, 13A neon switched fused spur £6.69

The NBS52 spur shows the other side of the story. BG's NBS52 page lists 2 earth terminals and certification to BS 1363 Part 4.

FAQs

Yes. BG's instructions say decorative products must have an earth connection between the front plate and the back box. They also say the box earth terminal must be linked to the accessory earth terminal where one is fitted. A metal plate can become live in a fault, so it needs an earth path.

Not safely. If the back box has no earth conductor to connect to, the plate has nothing to bond to, so do not fit a metal one. Ask a registered electrician to check the circuit. A plastic switch is the straightforward alternative while the wiring is assessed.

BG says to consult a competent person registered with an electrical self-certification scheme. Our Part P guide says a like-for-like switch replacement is not notifiable in England. A plastic-to-metal swap adds an earthing requirement, so we would have a registered electrician check the box and test the circuit.

BG's manual gives 16mm for profiled one and two gang plates, and 25mm for three, four and six gang. Our NBS12 and NBS13 pages also say 16mm. BG's specification sheet disagrees on three gang, so fit a 25mm box there. Flat plates need 25mm.

Green and yellow. BG's instructions say all bare earth wires must be sheathed with green/yellow sleeving. That covers the bare conductor in twin and earth cable as well as any short link you make between the back box and the plate. Check that the sleeving is not trapped under the plate.

Yes, every metal-faced accessory needs an earth connection. Socket and spur circuits normally carry an earth conductor already. BG's NBS52 page lists 2 earth terminals. Our metal clad guide says the box and faceplate are conductive, so they must be earthed.

Related reading

Part P: Can You Replace a Socket or Switch Yourself?What counts as notifiable work in England.
Metal Clad Sockets and Switches GuideWhy the box and faceplate must be earthed.

Earth the plate, then fit it

Check the box for an earth, make the links BG asks for and match the box depth. The full Nexus Metal brushed steel range is in stock.

Shop BG Nexus Metal brushed steel