Panel Heater: Plug It In or Fit a Fused Spur?

Plug it in or wire it in? Two heaters from the same maker can give opposite answers, and the manual is the only place that settles it.

Quick answer

Panel heater fused spur or plug: the manual decides. Dimplex's bathroom panel heater needs a switched fused spur and is not suitable for a plug top. Its 2kW portable radiator ships with a fused plug. For a fixed heater, fit a double pole switched fused connection unit and take the fuse size from the manual.

3A / 13ADimplex's typical fuse split, at 700W
3mmminimum contact separation three Dimplex manuals ask for
35mmminimum box depth for BG Evolve fused units

On this page

Panel heater fused spur or plug: what decides it?

There is no single answer, because heater makers write the connection method into each manual. Some heaters ship with a plug. Others ship with a bare flex for fixed wiring. Follow the manual for your model, not a general rule.

The wording is blunt. A heater marked "not suitable for connection via a plug top" must go through a fused connection unit. Fitting a plug anyway means the manufacturer's instructions have not been followed.

Decision chart: read the heater manual, then use the supplied plug or a switched double pole fused connection unit Read the heater manual Plug top allowed Spur only Use the supplied plug Fuse set by the manual Keep the socket reachable Switched double pole FCU Flex outlet, fuse set by the manual No timer ahead of the heater

Two routes, and the manual picks which one applies.

What do real heater manuals say?

Dimplex publishes its manuals online, so you can compare what one maker asks for across different heaters.

Heater Connection the manual asks for Other conditions
Bathroom panel heater BPH100M, 1kW (manual) Switched fused spur. Not suitable for a plug top Double pole isolation with 3mm contact separation. Not below a fixed socket
XLE storage heater (manual) Peak supply by switched fused spur, off-peak by a 20A double pole switch Plug and socket must not be used. Not above or below a fixed socket
Quantum storage heater The same split: switched fused spur and 20A double pole switch Not above, below or in front of a fixed electrical point
ECR20Tie 2kW portable radiator Supplied with a plug fitted with a 10A fuse Not directly below a socket, and the socket must stay reachable

That is one brand and four different instructions. Several manuals also ban placing the heater above or below a fixed socket, so plan the spur position before you settle the heater position.

How do you pick the fuse for a fixed heater?

Dimplex's bathroom heater manual gives a typical split for 230V equipment: 3A up to 700W, and 13A above that. The fuse protects the heater's flex, so the manual's figure beats guesswork. The arithmetic is watts divided by 230.

Heater Power Current at 230V Fuse by Dimplex's split
300W towel rail 300W 1.30A 3A
1kW bathroom panel heater 1,000W 4.35A 13A
2kW fixed panel heater 2,000W 8.70A 13A

At 230V, 3A is 690W, so Dimplex's 700W cut-off is a rounded figure. Check the rating plate and the manual rather than relying on the rounding.

Why do manuals ask for double pole and 3mm?

Three of the Dimplex manuals above ask for a double pole isolating switch with at least 3mm of contact separation. A double pole switch breaks live and neutral together, so the heater is properly isolated when it is off.

BG lists its Evolve switched fused connection unit, the PCDBS52W, as double pole on its own product page. BG's Evolve spec sheet gives the box depth and the standard but no contact gap. Ask BG before you rely on it where a manual demands 3mm.

Watch out

An unswitched fused connection unit has no switch, so it cannot supply the double pole isolating switch a manual asks for. Use a switched unit, or add a separate isolator.

Can you put a timer or smart switch in front of a heater?

Check first. Dimplex's bathroom panel heater manual says it must not be connected through an external switching device such as a timer. A timer spur or smart switch ahead of the heater is exactly that.

The manual explains why: repeated switching could reset the heater's thermal cut-off and create a fire hazard. If you want scheduling, choose a heater with built-in controls.

What changes in a bathroom?

Bathrooms add a layer on top of the manual. Sockets are restricted there, so a plug-in heater is rarely an option. Choose a heater whose manual names the bathroom, as the BPH100M does, and wire it through a fused connection unit.

Zones, IP rating and RCD protection all apply. Have a registered electrician do and certify the work, and place the fused connection unit where the manual and the zones allow.

Where do heater connections go wrong?

  • Fitting a plug to a spur-only heater. The manual says not suitable for a plug top. Follow it.
  • Mounting the heater under a socket. Several Dimplex manuals say not to, and the storage heaters add above and in front.
  • Fusing by habit. Dimplex says to rate the fuse for the appliance's flex, with a typical split of 3A under 700W and 13A over.
  • Putting a timer ahead of the heater. Some manuals forbid it outright.
  • Boxing an Evolve unit too shallow. BG's minimum for its Evolve fused units is 35mm.

Which fused connection unit should you buy?

For a fixed heater, choose a switched, double pole unit with a flex outlet. TEO's fused connection units collection lists 55 units. The BG Evolve PCDBS52W in Brushed Steel is £7.18. The same unit bundled with a 35mm steel back box is £9.85. For a metal look, see Nexus Metal Brushed Steel.

  • Manual checked: plug, spur, or either.
  • Unit is switched and double pole where the manual asks for isolation.
  • Fuse set from the manual: 3A up to 700W by Dimplex's split, 13A above.
  • Back box at least 35mm for Evolve fused units.
  • No timer or smart switch ahead of the heater.

Prices checked 31 October 2026.

Related reading

Fused Connection Units UK: Switched vs Unswitched

What a fused connection unit does, and when you need the flex outlet version.

Why Bathrooms Only Get a Shaver Socket, Not a 13A One

How BS 7671 bathroom zoning limits sockets, and what is allowed instead.

Frequently asked questions

It depends on the model. Dimplex's bathroom panel heater BPH100M needs a switched fused spur and is not suitable for a plug top. Other heaters ship with a plug. Read the manual for your exact model, because the connection method is written there.

Use the figure in the manual. Dimplex's bathroom heater guidance gives a typical split of 3A up to 700W and 13A above that, chosen to protect the flex. At 230V, 3A is 690W and 13A is 2,990W, so check the rating plate too.

Not if the manual says otherwise. Dimplex's bathroom panel heater manual says the heater must not be connected through an external switching device such as a timer, because it could reset the thermal cut-off. Use the heater's own controls instead.

Where the manual asks for a double pole isolating switch, yes. Three Dimplex manuals ask for a contact separation of at least 3mm. BG lists its Evolve switched fused connection unit as double pole, but its spec sheet gives no contact gap, so confirm with BG.

Several Dimplex manuals say not to. The bathroom panel heater says not immediately below a fixed electrical point, and the storage heaters add above or in front. Plan the heater position first, then put the spur and socket elsewhere on the wall.

BG's spec sheet gives a minimum mounting box depth of 35mm for the Evolve switched and unswitched fused connection units. TEO also lists the PCDBS52W with a 35mm steel back box. Check the box depth before you order any bundle.

Match the connection to the manual, then buy the spur